	<item>
		<title>
		By: Newsletter: August 10, 2014 &#124; Notes from MWhite		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-479</link>

		<dc:creator><![CDATA[Newsletter: August 10, 2014 &#124; Notes from MWhite]]></dc:creator>
		<pubDate>Sun, 10 Aug 2014 18:26:21 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-479</guid>

					<description><![CDATA[[&#8230;] VAAI but I have not done the same with NFS.  Here is some good info on block and VAAI, and here is what you need for NFS.  Here is some additional first rate information on [&#8230;]]]></description>
			<content:encoded><![CDATA[<p>[&#8230;] VAAI but I have not done the same with NFS.  Here is some good info on block and VAAI, and here is what you need for NFS.  Here is some additional first rate information on [&#8230;]</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Avnish		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-478</link>

		<dc:creator><![CDATA[Avnish]]></dc:creator>
		<pubDate>Thu, 26 Jun 2014 06:19:41 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-478</guid>

					<description><![CDATA[Excellent post !!!]]></description>
			<content:encoded><![CDATA[<p>Excellent post !!!</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: magander3		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-477</link>

		<dc:creator><![CDATA[magander3]]></dc:creator>
		<pubDate>Tue, 24 Jun 2014 11:11:59 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-477</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-476&quot;&gt;Mohammed Salem&lt;/a&gt;.

Thanks Mohammed, i was able to download the doc.
Will have a look later today.

//Magnus]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-476">Mohammed Salem</a>.</p>
<p>Thanks Mohammed, i was able to download the doc.<br />
Will have a look later today.</p>
<p>//Magnus</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Mohammed Salem		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-476</link>

		<dc:creator><![CDATA[Mohammed Salem]]></dc:creator>
		<pubDate>Tue, 24 Jun 2014 09:47:43 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-476</guid>

					<description><![CDATA[I found the whitepaper i was looking for :) .Starting with EMC VNX OE 7.x, a new functionality was added to monitor VAAI from the CS. Let me know if you cannot access it and I will send it offline. 

http://peru.emc.com/collateral/hardware/white-papers/h8292-vaai-with-nfs-on-vnx-wp.pdf]]></description>
			<content:encoded><![CDATA[<p>I found the whitepaper i was looking for 🙂 .Starting with EMC VNX OE 7.x, a new functionality was added to monitor VAAI from the CS. Let me know if you cannot access it and I will send it offline. </p>
<p><a href="http://peru.emc.com/collateral/hardware/white-papers/h8292-vaai-with-nfs-on-vnx-wp.pdf" rel="nofollow ugc">http://peru.emc.com/collateral/hardware/white-papers/h8292-vaai-with-nfs-on-vnx-wp.pdf</a></p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: magander3		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-475</link>

		<dc:creator><![CDATA[magander3]]></dc:creator>
		<pubDate>Sat, 21 Jun 2014 13:01:18 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-475</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-473&quot;&gt;Mohammed Salem&lt;/a&gt;.

Thanks Mohammed. As you mention, some storage solutions offers ways to monitor these things. Let me know your findings.]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-473">Mohammed Salem</a>.</p>
<p>Thanks Mohammed. As you mention, some storage solutions offers ways to monitor these things. Let me know your findings.</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: magander3		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-474</link>

		<dc:creator><![CDATA[magander3]]></dc:creator>
		<pubDate>Sat, 21 Jun 2014 12:59:46 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-474</guid>

					<description><![CDATA[In reply to &lt;a href=&quot;https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-472&quot;&gt;Rickard Nobel&lt;/a&gt;.

Thanks Rickard, totally agree]]></description>
			<content:encoded><![CDATA[<p>In reply to <a href="https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-472">Rickard Nobel</a>.</p>
<p>Thanks Rickard, totally agree</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Mohammed Salem		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-473</link>

		<dc:creator><![CDATA[Mohammed Salem]]></dc:creator>
		<pubDate>Sat, 21 Jun 2014 11:33:22 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-473</guid>

					<description><![CDATA[Excellent post Magnus, From my experience with EMC products we have extra level of monitoring VAAI, For instance, In SYMMETRIX you can monitor the VAAI from the array itself (requires EMC support to use inlines) The output is awesome. It will display in-depth information However you need to be aware of SCSI stack. For NFS, I am not sure but i believe we can check something as well from the VNX box. I will check and get back to you. What i want to say is that there might be an alternative methods to monitor VAAI via the storage array..]]></description>
			<content:encoded><![CDATA[<p>Excellent post Magnus, From my experience with EMC products we have extra level of monitoring VAAI, For instance, In SYMMETRIX you can monitor the VAAI from the array itself (requires EMC support to use inlines) The output is awesome. It will display in-depth information However you need to be aware of SCSI stack. For NFS, I am not sure but i believe we can check something as well from the VNX box. I will check and get back to you. What i want to say is that there might be an alternative methods to monitor VAAI via the storage array..</p>
]]></content:encoded>
		
			</item>
		<item>
		<title>
		By: Rickard Nobel		</title>
		<link>https://magander.se/vsphere-nfs-and-vaai-monitoring/#comment-472</link>

		<dc:creator><![CDATA[Rickard Nobel]]></dc:creator>
		<pubDate>Sat, 21 Jun 2014 10:34:37 +0000</pubDate>
		<guid isPermaLink="false">http://magander.se/?p=3763#comment-472</guid>

					<description><![CDATA[&quot;Anyone aware of another way to monitor VAAI for NFS attached storage for vSphere, please let me know.&quot;

Not totally accurate, but one indirect way could be to use ESXTOP while doing a full clone and in the &quot;n&quot; view  watch the specific vmnics used by NFS and see that the network traffic should be much lower than using normal full copy through the network. :)

Also the IO against the datastore should be low(er) in the &quot;u&quot; view.]]></description>
			<content:encoded><![CDATA[<p>&#8220;Anyone aware of another way to monitor VAAI for NFS attached storage for vSphere, please let me know.&#8221;</p>
<p>Not totally accurate, but one indirect way could be to use ESXTOP while doing a full clone and in the &#8220;n&#8221; view  watch the specific vmnics used by NFS and see that the network traffic should be much lower than using normal full copy through the network. 🙂</p>
<p>Also the IO against the datastore should be low(er) in the &#8220;u&#8221; view.</p>